Phoenix Fused Modular Terminal Block St 4-hanging 243036547

0.00
AED

(VAT included)


Product details
Fast connection separating lever fuse terminal block, black, for 5 x 20 mm cartridge fuses, led for 24 v dc nbsp
Generalcat number1number of connections2nominal cross section4 mm²colorblackinsulation materialconform to paule 94 fireproof classv0maximum power loss for nominal condition1.6 wfuse / 5 x 20fuse typocam / ceramic / . . . Rated impulse voltage4 kimpurity class3impulse voltage categoryiiiiinsulation material groupmaximum power lossmax. 1.6 w (single regulation of the fuse terminal at overload) max. 1.6 w (arrangement of many fuse terminal blocks in the interconect at overload)max. 4 w (single arrangement of the terminal block with fuse in short circuit) max. 2.5 w (arrangement of many fuse terminals in short circuit) led voltage range 12 v ac/dc. . . 30 v ac/dc current range 0.31 ma. . . 0.95 standard suitable connection ec 60947-7-3 maximum load current 6.3 a (current is determined by the fuse used) nominal current 6.3 nominal voltage 24 v side no relative insulation material temperature index (elec.
ul 746 b)130 ° Thermal insulation material temperature index (din en 60216-1 (vde 0304-21)) 130 ° Static insulation material application in ccol-60 ° Fire behavior in cdemiryolu vehicles (din 5510-2)passed the testflame test method (din en 60695-11-10)v0oxygen index (din en iso 4589-2)gt 32 %nf f16-101, nf f10-102 class i2nf f16-101, nf f10-102 class f2surface fire resistance nfpa 130 (astm e 162)passedspecial optical smoke density nfpa 130 (astm e 662)passedsmoke gas toxicity nfpa 130 (smp 800c)passedcalorimetric heat release nfpa 130 (astm e 1354)28 mj/kgfire protection in railway vehicles (din en 45545-2) r22hl 1 - hl 3fire protection in railway vehicles (din en 45545-2) r23hl 1 - hl 3fire protection in railway vehicles (din en 45545-2) r24hl 1 - hl 3fire protection in railway vehicles (din en 45545-2) r26hl 1 - hl 3dimensionswidth6.2 mmlength61.5 mmheight ns Conductor cross-sectional area0.08 mm²single core max. Conductor cross-sectional area6 mm²multi-core min. Conductor cross-sectional area is 0.08 mm², multi-core max. Conductor cross-sectional area 4 mm², minimum conductor cross-sectional area in awg. 28 conductor cross-sectional area max. 10multi-core conductor cross-sectional area, thimble without plastic sheath, min. 0.14 mm²multi-core conductor cross-sectional area, with thimble without plastic sheath, max. 4 mm²multi-core conductor cross-sectional area, with plastic sheath thimble, min. 0.14 mm²multi-core conductor cross-sectional area, with plastic sheath thimble, max. 4 mm²same section 2 conductors, multi-core, twin thimble with plastic sheath, min. 0,5 mm²2 conductors of the same section, stranded, twin ferrule with plastic jacket, max. 1 mm² connection type, wired connection, cable stripping length 8 mm. . . 10 mm inner cylindrical indicatora4standards and regulationsconform to standard connectioncsaiec 60947-7-3ul 94 compliant fire resistance classv0fire protection in railway vehicles (din en 45545-2) r22hl 1 - hl 3 hl 1 - hl 3 hl 1 - hl 3 hl 1 - hl 3fire protection in railway vehicles (din en 45545-2) r23hl 1 - hl 3 hl 1 - hl 3 hl 1 - hl 3 hl 1 - hl 3fire protection in railway vehicles (din en 45545-2) r24hl 1 - hl 3 hl 1 - hl 3 hl 1 - hl 3 hl 1 - hl 3fire protection in railway vehicles (din en 45545-2) r26hl 1 - hl 3 hl 1 - hl 3 hl 1 - hl 3 hl 1 - hl 3china rohsenvironmentally friendly usage time Yoksınıflarınarmaecl@ss